periNODE

Single Pair Ethernet adapters

Put 4-20 mA, 0-10 V, 24 V digital and Modbus RTU devices on the network, with no protocol gateway and no PLC change

What is a Single Pair Ethernet adapter?

A Single Pair Ethernet adapter connects a sensor or device without an Ethernet interface to an SPE network. periNODE is Perinet's range of SPE adapters. Each one sits beside its sensor, powers it where needed, reads its 4-20 mA, 0-10 V, 24 V digital or Modbus RTU signal and publishes the data over MQTT from its own IP address on 100BASE-T1, with a REST API for direct access. One hybrid periLINE cable carries data and 24 V DC to a periSWITCH or periSTART, so there is no separate protocol gateway, remote I/O station or PLC input in the path.

Sensor already wired into a 4-20 mA loop the PLC depends on? Use periSNOOP 4-20mA instead. It sits in the loop, sends a copy of the value to IT and the PLC keeps its signal. How to get sensor data without changing the PLC compares the routes.

periNODE 4-20mA

Add a 4-20 mA sensor

periNODE 0-10V

Add a 0-10 V sensor

periNODE GPIO

Machine states and counts

periNODE Modbus

Modbus RTU, passive or active

Which periNODE for which signal?

Diagram: a sensor or machine signal connects to periNODE, where the first IP address sits; a hybrid periLINE cable runs to periSWITCH or periSTART, which joins standard Ethernet; IT systems receive the data over MQTT and REST.
AdapterSignalUse it forWhat IT receives
periNODE 4-20mA4-20 mA or 0-20 mAA new measuring point: add an off-the-shelf 4-20 mA sensorThe value in physical units
periNODE 0-10V0-10 VA new measuring point: add an off-the-shelf 0-10 V sensorThe value in physical units
periNODE GPIO24 V digital, two input/output channelsExisting machine signals such as a running contact, or switching sensors you add; machine states and counts for OEEStates and counts
periNODE ModbusModbus RTU over RS-485Passive: listen to a bus the PLC already polls, sending nothing. Active: connect a single device nothing polls todayRTU frames over MQTT; values with units via periMICA and the Modbus IoTizer

periNODE adapters by signal type. All four use 100BASE-T1 (IEEE 802.3bw), the M8 hybrid connector to IEC 63171-6, 24 V DC, and MQTT and REST.

Not sure which adapter fits your installation? Tell us your signal type and what the PLC uses today. An engineer will recommend the setup.

Ask an engineer

What every periNODE does

100BASE-T1

Single Pair Ethernet, IEEE 802.3bw

IP65/67

-40 °C to +70 °C (GPIO IP67)

24 V DC

Data and power on one hybrid cable

MQTT + REST

Open interfaces, any broker or IT system

  • Announces itself under its own hostname (mDNS) and is configured in a browser.
  • Optional 256-bit end-to-end encryption and mutual TLS.
  • Reach: Perinet has measured 100BASE-T1 at up to 180 m on installed Cat 5e (PRN100900).

30 min

from mounting to OEE data, with no change to the PLC

Specialty-lubricants filling line in Spain: periNODE GPIO and periMICA, with solution partner ZentinelMDS. See the OEE use case

Built like control hardware. Owned by IT.

periNODE is industrial hardware: 24 V DC, IP65/67, -40 °C to +70 °C, nothing to program. Where it taps an existing machine, it leaves the controls alone: periNODE GPIO reads a running contact in parallel, periNODE Modbus listens without sending a single frame. Every adapter has its own hostname and web interface, so IT sees each data point directly. And the data path belongs to the team that uses the data, so someone notices when it stops.

Questions

What are the alternatives to IO-Link masters and remote I/O for connecting sensors to MQTT or REST?

IO-Link masters and remote I/O stations publish from a central point: every sensor is wired back to the master or I/O station, which talks to IT directly or through an edge device. periNODE puts the network interface at the sensor instead. Each adapter has its own IP address and publishes over MQTT, with a REST API, so there is no master or I/O station in between. IO-Link vs Single Pair Ethernet compares the two in detail.

Can periNODE connect to a sensor that already feeds a PLC?

For digital signals, yes: periNODE GPIO reads a 24 V signal such as a running contact. On a Modbus RTU bus a PLC already polls, periNODE Modbus listens in passive mode without sending anything. For a 4-20 mA loop the PLC depends on, use periSNOOP 4-20mA.

Do I need a gateway or a PLC change?

No. Each periNODE publishes directly over MQTT and offers a REST API. A periSWITCH or periSTART connects the Single Pair Ethernet segment to standard Ethernet, and the PLC program stays as it is.

Which sensors work with periNODE?

Any off-the-shelf sensor with a 4-20 mA, 0-10 V, 24 V switching or Modbus RTU interface and a 24 V DC supply within the adapter's output.

More background: Single Pair Ethernet explains the standards, reach and power.

Not sure which adapter fits your installation?

Tell us your signal type, what the PLC uses today and where the data should go. An engineer will recommend the adapter and the setup.

What happens next

  1. You tell us the signal and where the data needs to go.
  2. A Perinet engineer looks at your installation.
  3. You get a recommended adapter and setup. No sales call unless you want one.